Amana AMV6167BD Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Micro-ondes Amana AMV6167BD. Amana AMV6167BD User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
A
B
C
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
VENTING REQUIREMENTS
AMV5206BA
AMV6167BD
Electrical: 120-volt, 60-Hz, AC-only. AMV5206BA requires 15-amps and
1.7 kilowatts and AMV6167BD requires 13-amps and 1.5 kilowatts.
This product must be connected to a supply circuit of the proper voltage
and frequency. Wire size must conform to the requirements of the National
Electrical Code or the prevailing local code for this kilowatt rating. The
power supply cord and plug should be brought to a separate 20 amp
branch circuit single grounded outlet. The outlet box should be located in
the cabinet above the microwave oven. The outlet box and supply circuit
should be installed by a qualified electrician and conform to the National
Electrical Code or the prevailing local code.
Over the Range Microwave Oven
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P710-60
09-11-08
CABINET OPENING DIMENSIONS
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should
be used.
The total length of the vent system including straight vent, elbow(s),
transitions and wall or roof caps must not exceed the equivalent of 140 ft
(42.7 m) for either type of vent.
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following
carefully.
NOTE: It is important that venting be installed using the most direct route
and with as few elbows as possible. This ensures clear venting of exhaust
and helps prevent blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent length
for each vent piece used in the system. See the following examples:
Backsplash
16-½ "
33"min.
5"
3
0
"
Bottom edge of
cabinet needs
to be 33" or
more from the
cooking
surface
®
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have
to be cut to fit, using tin snips, in order to allow free movement of the damper.
TNELAVIUQESECEIP TCUD
LENGTH x
NUMBER
USED =
EQUIVALENT
LENGTH
Roof Cap 24 Ft. x (1) = 24 Ft.
12 Ft. Straight Duct
(6" Round)
12 Ft. x (1) = 12 Ft.
Rectangular-to-Round
Transition Adaptor*
5 Ft. x (1) = 5 Ft.
Equivalent lengths of duct pieces are based on actual
tests and reflect requirements for good venting
performance with any vent hood.
Total Length = 41 Ft.
(7.3 m)
(3.7 m)
(1.5 m)
(7.3 m)
(3.7 m)
(1.5 m)
(12.5 m)
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be
prepared at the time it is constructed by leaving enough space between the wall studs to accommodate
exhaust.
TNELAVIUQESECEIP TCUD
LENGTH* x
NUMBER
USED =
EQUIVALENT
LENGTH
Roof Cap 40 Ft. x (1) = 40 Ft.
3 Ft. Straight Duct
(3¼" x 10"
Rectangular)
3 Ft. x (1) = 3 Ft.
90° Elbow 10 Ft. x (2) = 20 Ft.
Equivalent lengths of duct pieces are based on actual
tests and reflect requirements for good venting
performance with any vent hood.
Total Length = 63 Ft.
(12.2 m)
(1 m)
(3 m)
(12.2 m)
(1 m)
(6.1 m)
(19.2 m)
Width (A) Depth (B) Height (C)
AMV5206BA 29-7/8" 17" 16-15/16"
(75.9 cm) (43.2 cm) (43.0 cm)
AMV6167BD 29-7/8" 15-21/32" 16-15/16"
(75.9 cm) (39.8 cm) (43.0 cm)
NOTES:
• The space between the cabinets must be 30" (76.2 cm) wide
and free of obstructions.
• This microwave oven is for installation over ranges up to 33"
(83.8 cm) wide.
• If you are going to vent your microwave oven to the outside,
see Venting Requirements for exhaust duct preparation.
When installing the microwave oven beneath smooth flat
cabinets be careful to follow the instructions on the top
cabinet template for power cord clearance.
Vue de la page 0
1

Résumé du contenu

Page 1

ABCPRODUCT MODEL NUMBERSPRODUCT DIMENSIONSVENTING REQUIREMENTSAMV5206BAAMV6167BDElectrical: 120-volt, 60-Hz, AC-only. AMV5206BA requires 15-amps and1

Commentaires sur ces manuels

Pas de commentaire