Room Air Conditioner & Heat Pump
Use and Care Manual
Introduction
Room air conditioners cool, dehumidify, and filter air inside
your home. Heat pump and electric heat models offer both
heating and cooling. Opening sections of manual provide
general information for all room air conditioner models.
Operating Controls section describes operation of controls
for each model. After reading the opening sections, turn to
Operating Controls section and find the panel layout that
matches the model of your unit.
Read entire manual thoroughly before beginning installation
and operation of your new room air conditioner. Be sure you
have all necessary tools and materials on hand for the job.
Study illustrations to familiarize yourself with important
details of the installation process. Review manual for oper-
ating instructions.
NOTE
1. Mechanical experience is required to install air condi-
tioner.
2. Installation can take from 1 to 3 hours, depending on
installer’s knowledge and skill.
3. If you encounter problems during installation, call our
consumer information line toll-free at 1-877-254-4729. If
your problem cannot be resolved by phone, contact an
authorized Amana
®
brand servicer. Contact and service
will be at your expense.
Safety Information
Be sure electrical service is adequate for chosen model of air
conditioner. Complete electrical rating for unit is found on
serial plate located behind front grille. Electrical outlet must
be close enough to unit for power cord to reach without strain.
Air conditioner should be the only appliance on individual
circuit.
For personal safety and to avoid possible damage to appli-
ance or home, observe all safety instructions highlighted by
symbol shown below.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.
After installing unit, reread instructions to ensure each step
is complete and that all parts are fastened in place. For best
results and to minimize installation time, perform all proce-
dures in the order shown.
Contents
Introduction .................................................................. 1
Safety Information ....................................................... 1
Normal Care and Maintenance .................................. 3
Installation Instructions ............................................... 5
Electrical Requirements.............................................. 5
General Instructions ...................................................11
Operating Controls .................................................... 12
Before Calling Service .............................................. 13
When Service Is Required ........................................ 14
Any Questions? .......................................................... 14
Through-The-Wall Installation Instructions ............. 15
Warranty..................................................................... 18
©2006 Goodman Company, L.P.
Effective: November 2006
®
Part. No. 120B
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - Use and Care Manual

Room Air Conditioner & Heat PumpUse and Care ManualIntroductionRoom air conditioners cool, dehumidify, and filter air insideyour home. Heat pump

Page 2 - Unpacking

10INS TALL THE AIR CONDITIONERIN THE CASESlide the airconditioner into the case. Do notpush on thecontrols or thefinned coils. Make sure the air co

Page 3 - Delay Fuse Nameplate

11General Operating InstructionsWhile operation of all units is similar, controls vary slightlyfrom model to model. Operating Controls section showsco

Page 4 - Figure H

12Fan ControlOFF – Completely shuts off the unit. To prevent blowingfuses, wait three minutes after turning the unit off beforeturning it on again.LO

Page 5 - Air Conditioner

13Before Calling ServicePROBLEM POSSIBLE CAUSE SUGGESTED REMEDY UNIT WILL NOT RUN No power to unit Push reset button on power cord. Set Fan Contro

Page 6

14When Service Is RequiredYour room air conditioner dealer can give you the name ofyour nearest Authorized Service Center. Help them giveyou prompt s

Page 7

1526"Dimension of Bottom Rail"4”Front ofouter caseBottom railOuter Case Dimensions(chassis removed)General InstructionsAll Amana® brand Comp

Page 8

16In order to reinstall the chassis and re-attach the air conditioner front cover, theinstalled outercase must be square and level from side to side.

Page 9

17When case is properly positioned in opening, use woodshims to fill any gaps between case and finished opening,especially in area where case will be

Page 10 - Installation Instructions

18©2006 Goodman Company, L.P.Effective: November 2006Part No. HI-120B$($+3%&3%(3%+)RUIXUWKHULQIRUPDWLRQDERXWWKLVZDUUDQW\FRQWDFW*

Page 11 - Outer Case

2OWNER'S PRODUCT IDENTIFICATIONMODEL NUMBERSERIAL NUMBERMANUFACTURING NUMBEROwner's NameAddressCity State Zip / / Date of Pu

Page 12 - Operating Controls

3NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115VNEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V ratedat 12 amperes orlessNEMA No. 6-20P NEMA No. 6-20R

Page 13 - Before Calling Service

4Annual InspectionIt is suggested that your unit be inspected by your dealer orservicer once a year. It is advisable to have the outer caseremoved an

Page 14 - When Service Is Required

5InstallationInstructionsAir ConditionerBEFORE YOU BEGINRead these instructions completely and carefully.• IMPORTANT - Save these instructions for loc

Page 15 - brand Room Air Conditioner

6Type A (6)V-support (2)Window lockingbracket (2)TopmountingrailRightaccordionpanelFoam topwindow gasketWindowsash sealLeftaccordionpanelType B (4) T

Page 16 - Masonry Construction

717 3/8" min.30 to 41" min.(With accordion panels)26" min.(Without accordion panels)1/2" higherthan frameStormwindowframeWoodStool

Page 17 - Thicker Than 8 1/2-inches

8PREPARE THE CASEInstall the top m ounting rail w ith 4 type Bscrews from the inside of the case.Insert the frames for the accordion panelsinto the to

Page 18 - :$55$17<

9Installation InstructionsINSTALL THE CASEIN THE WINDOW (cont.)Adjus t the leveling bolts and nuts against theoutside wall so that the case has a slig